Desenvolvimento e validação inicial de uma solução para ensino remoto de audiometria tonal limiar

Development and Initial Validation of a Solution for Remote Teaching of Pure Tone Audiometry

Trentin, G. Enga. de Controle e Automação, UFSC, SC, Brasil, gutotrentin@gmail.com
Bagnara, B. O. Fonoaudióloga, UFSC, SC, Brasil, brunabagnara07@gmail.com
Murta B. H. P. Laboratório de Vibrações e Acústica, UFSC, Florianópolis, SC, Brasil, be.murta@gmail.com
Lara A. A. S. Enga. de Controle e Automação, UFSC, SC, Brasil, angelo.asl20@gmail.com
Zucki F. M. Fonoaudióloga, UFSC, SC, Brasil, fernanda.zucki@ufsc.br
Paul S. Laboratório de Vibrações e Acústica, UFSC, Florianópolis, SC, Brasil, stephan.paul@ufsc.br

Resumo

Com o COVID-19 as atividades práticas no ensino, normalmente realizadas em ambiente laboratorial ou clínico, como a prática da audiologia clínica, precisaram ser reestruturadas. Para auxiliar o ensino remoto em audiologia, foi desenvolvido para a plataforma perSONA um módulo específico para simular um audiômetro típico e permitir que alunos pratiquem a condução de audiometria tonal limiar (ATL) por via aérea utilizando computadores pessoais. O novo módulo foi desenvolvido em C#, incluindo 1) a calibração psicoacústica, 2) a reprodução de ruídos de mascaramento e tons puros para fins de ATL. A calibração psicoacústica, baseada no limiar auditivo (LA) do usuário, visa garantir resultados adequados nas ATL, uma vez que 1) os transdutores de som (diferentes fones de ouvido usados pelos alunos em casa) tem headphone FRFs desconhecidos e nenhum LA, a priori, pode ser considerado e codificado no módulo e 2) os alunos não tem os equipamento para calibração instrumental. Ruídos de mascaramento, para uso na investigação de LA tonais por condução aérea, foram gerados a partir do ruído branco filtrado com filtros de oitava. Para uma reprodução de som adequada no Windows X64, um driver de áudio específico (ASIO4ALL) foi incluído no instalador do software. O módulo foi validado de duas formas: 1) professores e alunos de Audiologia avaliaram sua interface e funcionamento por meio de questionários eletrônicos; 2) Validação instrumental da reprodução sonora, avaliando os níveis de pressão sonora, níveis de audibilidade e frequências de reprodução de tons puros utilizando um manequim KEMAR com fones Sennheiser HD580, HDA 300 e C3Tech e utilizando o módulo de ATL em diferentes computadores com diferentes placas de som. Os resultados mostraram-se muito satisfatórios. Contudo a reprodução correta dos níveis sonoros e níveis auditivos requer o driver ASIO4ALL, contornando equalizadores e compressores de volume presentes por padrão nos drivers das placas de áudio do Windows 10.

Palavras-chaves:  
audiômetro
,
simulador
,
Windows
,
ensino.

Abstract

Due to COVID-19, practical activities in teaching, normally carried out in a laboratory or clinical environment, such as the practice of clinical audiology, needed to be restructured. To assist distance teaching in audiology, a specific module to simulate a typical audiometer and allow students to practice conducting pure tone air conduction audiometry (PTA) using personal computers was developed for the perSONA platform. The new module was developed in C#, including functionalities such as 1) psychoacoustic calibration, 2) reproduction of masking noise and pure tones for PTA. Psychoacoustic calibration, based on the user's auditory threshold (AT), is required to obtain adequate results in PTA, since 1) the sound transducer's (different headphones used by students at home) HpFRFs are unknown and no AT, a priori, can be considered and coded in the module and 2) users/students do not have the equipment for an instrumental calibration. Masking noise, to be used in the PTA, was generated filtering white noise by octave filters. For proper sound reproduction on Windows X64, a specific audio driver (ASIO4ALL) has been included in the software installer. The module was validated by: 1) audiology teachers and students evaluating its interface and functioning through electronic questionnaires; 2) Instrumental validation of the sound reproduction, assessing SPL, hearing levels (HLs) and pure-tone frequencies using a KEMAR manikin together with Sennheiser HD580, HDA300 and c30 Tech headphones and running the ATL module on different computers with different sound cards. Results proved to be very satisfactory, but correct reproduction of SPLs and HLs is possible only usingthe ASIO4ALL driver, as this one circumvents all equalizers and volume compressors present by default in Windows 10 audio card drivers.

Keywords:  
pure tone audiometer
,
simulator
,
Windows
,
teaching.

Referências

[1] Murta, Bernardo Henrique Pereira et al. Plataforma para ensaios de percepção sonora com fontes distribuídas aplicável a dispositivos auditivos: persona. 2019.
[2] Paul, S. Material de aula da disciplina FON 7208, 2020.
[3] Fonoaudiologia, Conselho Federal. Guia de orientações na avaliação audiológica básica. Elaboração: Sistema de Conselhos de Fonoaudiologia Colaboração: Sociedade Brasileira de Fonoaudiologia, 2017.
[4] Lopes, AC; Munhoz, GS; Bozza, A; EM, Boéchat; PL, Menezes; CM, Couto; ACF, Frizzo; RC, Scharlach e ART., Anastasio. Diagnóstico audiológico. Tratado de Audiologia, 2:55–178, 2015.
[5] Wazlawick, Raul. Análise e design orientados a objetos para sistemas de informação: Modelagem com UML, OCLeIFML. Elsevier Brasil, 2016.
[6] Paul, Stephan. Binaural recording technology: A historical review and possible future developments. Acta acustica united with Acustica, 95(5):767–788, 2009
Publicado em:
01/09/2022