Desenvolvimento de um sistema de monitoramento de níveis de pressão sonora baseado em PC/DAQ NI USB-9234 para o monitoramento sonoro na região da Pampulha em Belo Horizonte – MG

Silva, J. G. dB Laboratório de Engenharia Acústica, Belo Horizonte, MG, Brasil, junior@dbacustica.com.br
Cavalcante, K. V. S. M. dB Laboratório de Engenharia Acústica, Belo Horizonte, MG, Brasil, krisdany@dbacustica.com.br
Rezende, V. M. dB Laboratório de Engenharia Acústica, Belo Horizonte, MG, Brasil, vanessa@dbacustica.com.br
Andrade, L. H. M. dB Laboratório de Engenharia Acústica, Belo Horizonte, MG, Brasil, luishenrique@dbacustica.com.br
Mota, L. C. C. dB Laboratório de Engenharia Acústica, Belo Horizonte, MG, Brasil, lorena@dbacustica.com.br
Almeida, C.G. dB Laboratório de Engenharia Acústica, Belo Horizonte, MG, Brasil, carolina@dbacustica.com.br
Dias, L. S. dB Laboratório de Engenharia Acústica, Belo Horizonte, MG, Brasil, lucas@dbacustica.com.br
Marques, H. F. M. Secretaria Municipal de Meio Ambiente, Belo Horizonte – MG, Brasil, hmarques@pbh.gov.br

Resumo

Este artigo apresenta resultados do desenvolvimento de um sistema de monitoramento de níveis de pressão sonora, a ser aplicado na região do Conjunto Moderno da Pampulha, em Belo Horizonte – MG. Esta região teve seu tombamento pela UNESCO, como patrimônio cultural da humanidade, em 2016. Os estudos compreenderam o desenvolvimento de um sistema de medições de níveis de pressão sonora, para aplicação em atendimento ao método de monitoramento da ABNT NBR 10151:2019. Programado em linguagem LabVIEW, para PC/Windows, o sistema utiliza como hardware uma placa de aquisição e conversão analógico/digital modelo NI USB-9234. Esse artigo apresenta os estudos para o desenvolvimento do sistema de monitoramento e os resultados dos testes eletroacústicos, obtidos em bancada. Este trabalho de pesquisa foi financiado com recursos do Fundo Municipal de Defesa Ambiental – FMDA, através do chamamento público FMDA/BH nº 01/2018.

Palavras-chaves:  
eletroacústica
,
LabVIEW
,
método de monitoramento
,
processamento de sinais
,
ruído ambiental.

Abstract

This article presents the results of the development of a system for monitoring sound pressure levels, to be applied in the region of the Pampulha Modern Ensemble, in Belo Horizonte – MG, Brazil. This region was declared by UNESCO in 2016 at World Heritage List. The studies comprised the development of a sound pressure level measurement system, for application in compliance with the monitoring method of ABNT NBR 10151:2019. Programmed in LabVIEW language, for PC/Windows, the system uses as hardware an analog/digital acquisition and conversion board, model NI USB 9234. This research work was financed with resources from the Municipal Environmental Defense Fund - FMDA, through the public call FMDA/BH nº 01/2018.

Keywords:  
electroacoustics
,
LabVIEW
,
monitoring method
,
signal processing
,
environmental noise.

Referências

[1] Guski, Rainer, Dirk Schreckenberg, and Rudolf Schuemer. "WHO Environmental Noise Guidelines for the European Region: A Systematic Review on Environmental Noise and Annoyance." International Journal of Environmental Research and Public Health 14.12 (2017): 1539. Web.
[2] Freire, S., and N. Gomes. "Advancing environmental noise pollution analysis in urban areas by considering the variation of population exposure in space and time." International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences. XL-4/W1 (2013): 155-60. Web.
[3] World Health Organization and the Joint Research Centre of the European Commission, “Burden of disease from environmental noise: quantification of healthy life years lost in Europe, World Health Organization,” Tech. Rep., WHO Regional Office for Europe, 2011.View at: Google Scholar.
[4] Associação Brasileira de Normas Técnicas, ABNT NBR 10151:2019, Acústica — Medição e avaliação de níveis de pressão sonora em áreas habitadas — Aplicação de uso geral.
[5] Alías, Francesc, and Rosa Ma Alsina-Pagès. "Review of Wireless Acoustic Sensor Networks for Environmental Noise Monitoring in Smart Cities." Journal of Sensors 2019 (2019): 1-13. Web.
[6] Bello, J. P., Silva, C., Nov, O., Dubois, R. L., Arora, A., Salamon, J., ... & Doraiswamy, H. (2019). Sonyc: A system for monitoring, analyzing, and mitigating urban noise pollution. Communications of the ACM, 62(2), 68 77. Disponível em:https://doi.org/10.48550/arXiv.1805.00889
[7] Picaut, J.; Can, A.; Fortin, N.; Ardouin, J.; Lgrange, M. Low-Cost Sensors for Urban Noise Monitoring Networks—A Literature Review. Sensors 2020, 20, 2256. Disponível em: https://doi.org/10.3390/s20082256
[8] Forouharmajd, Farhad, Zahra Mohammadi, Masoumeh Ahmadvand, and Farshad Forouharmajd. "Sound Pressure Level Tools Design Used in Occupational Health by Means of LabVIEW Software." International Journal of Environmental Health Engineering 4.1 (2015): 41. Disponível em: https://rnp primo.hosted.exlibrisgroup.com/permalink/f/vsvpiv/TN_ cdi_doaj_primary_oai_doaj_org_article_c1c54e04d0274 e3a80f0dc7dc7be7b16
[9] International Electrotechnical Commission, IEC 60651:1979, Sound Level Meters.
[10] International Electrotechnical Commission, IEC 60804:1985, Integrating-averaging sound level meters.
Publicado em:
01/09/2022