Valores de referência para trens tonais da norma IEC 61672-1 aplicados a um audiodosímetro

Reference values for tonal trains from IEC 61672-1 standard applied to an audiodosimeter

Santo, N. M. E. Inmetro – Laboratório de Electroacústica, Xerém, RJ, Brasil, nmsanto@Inmetro.gov.br
Zajarkievaiech, J.E.B. Total Safety (Calilab), São Caetano do Sul, SP, Brasil, enrique@totalsafety.com.br
Soares, Z.M.D. Inmetro – Laboratório de Electroacústica, Xerém, RJ, Brasil, zmsoares@inmetro.gov.br

Resumo

A IEC 61252 está em plena fase de revisão. Uma minuta do projeto de revisão da norma, circulada em 2018, tendia a torná-la mais próxima da IEC 61672 e, portanto, ficaria mais distante do contexto brasileiro. Isto porque a nossa legislação foi baseada na ANSI S1.25 (1991), que calcula a dose (D) e o nível médio Lav (ou Lavg) a partir do nível sonoro ponderado no tempo S (Slow). Além disso, para a dose, aplica-se uma ponderação energética que não coincide com a dobra natural de energia, um conceito estranho ao contexto da IEC 61252 ou IEC 61672. Em 2020 a IEC circulou a minuta 3WD IEC 61252 que, desta vez, incluía a dose como um parâmetro opcional. Esta inclusão representou uma nova janela de oportunidade para todos os países que, como o Brasil, utilizam parâmetros calculados com energia não-equivalente. Um grupo de discussão da ABNT realizou uma análise crítica da minuta, com contribuições diversas, para ser encaminhada à IEC como voto brasileiro. Uma das questões técnicas mais desafiadoras foi estabelecer uma conexão entre os trens tonais propostos na minuta e sua aplicabilidade para verificar a conformidade das medições de dose ou do nível médio, tal como definido no contexto brasileiro.

Palavras-chaves:  
audiodosímetro
,
exposição sonora
,
calibração periódica
,
trens tonais
,
pulsos senoidais.

Abstract

IEC 61252 is in the full review phase. A first draft of second Edition, circulated in 2018, tended to bring it closer to IEC 61672 and, therefore, would be further from the Brazilian context. This is because our legislation was based on ANSI S1.25 (1991), which calculates the dose (D) and the average sound level Lav (or Lavg) from the time-weighted sound level S (Slow). In addition, for the dose, an energy weighting that does not coincide with the natural energy bending applies, a concept foreign to the context of IEC 61672. In 2020 the IEC circulated the draft 3WD IEC 61252 which this time includes the dose as an optional parameter. This inclusion represents a new window of opportunity for all countries that, such as Brazil, use parameters calculated with non-equivalent energy. A discussion group of ABNT carried out a critical analysis of the draft, with various contributions, to be forwarded to the IEC as a Brazilian vote. One of the most challenging technical issues was to establish a connection between the tone bursts proposed in the draft and their applicability to verify the conformity of dose or average sound level measurements, as defined in the Brazilian context.

Keywords:  
exposure meter
,
noise dosimeter
,
periodic tests
,
tone burst
,
sinusoidal pulses.

Referências

[1] IEC 61252:1993 Electroacoustics - Specifications for personal sound exposure meters.
[2] IEC 61672-1:2013 Electroacoustics - Sound level meters - Part 1: Specifications.
[3] IEC 61672-2:2013 Electroacoustics - Sound level meters - Part 2: Pattern evaluation tests.
[4] IEC 61672-3:2013 Electroacoustics - Sound level meters - Part 3: Periodic tests.
[5] 3WD IEC 61252:2021.
[6] ANSI S1.25: 1991 Specification for Personal Noise Dosimeters.
Publicado em:
01/09/2022